COAXIAL CABLES
> > COAXIAL CABLES
  • RG58 A/U RG58/U RG58 C/U Coaxial Cable
  • RG58 A/U RG58/U RG58 C/U Coaxial Cable
  • RG58 A/U RG58/U RG58 C/U Coaxial Cable
  • RG58 A/U RG58/U RG58 C/U Coaxial Cable
  • RG58 A/U RG58/U RG58 C/U Coaxial Cable
  • RG58 A/U RG58/U RG58 C/U Coaxial Cable
  • Name:RG58 A/U RG58/U RG58 C/U Coaxial Cable
  • Model:RG58 A/U
  • Hit:457
Share This Product:
  • Description
  • Technical Parameters

1.

Cable Type
RG58 A/URG58/URG58 C/U
Inner ConductorTinned Plain Copper19 x 0.18mmφ 0.80mm19 x 0.18mm
DielectricLow Density PE
φ 2.95mmφ 2.95mmφ 2.95mm
Outer Conductor(Shield)Tinned Copper144 x 0.10mm112 x 0.13mm112x 0.13mm
Shield Coverage/93%95%95%
SheathPVC or LSZHφ 5.00mmφ 5.00mmφ 5.00mm

2.

Cable TypeRG58 A/URG58/GRG58 C/U
Impedance50±3 Ohm53±3 Ohm53±3 Ohm
Nominal Capacitance100 pF/m94 pF/m100 pF/m
Velocity of Propagation66%66%66%
Insulation Resistance
>2000 Mohm.Km>2000 Mohm.Km>2000 Mohm.Km
Inner Conductor Resistance 37.5 Ohm/Km35 Ohm/Km37.5 Ohm/Km
Outer Conductor Resistance 17 Ohm/Km16.5 Ohm/Km16.5 Ohm/Km
Test/Operating Voltage(Max)
/5 KV/2 KV5 KV/2 KV
Operating Temperature Range-30 ℃-+70 ℃-30 ℃-+70 ℃-30 ℃-+70 ℃
Screening Effectiveness(100-900MHz)>55 dB>55 dB>55 dB

3.

Cable TypeRG58 A/URG58/URG58 C/U
30-300 MHz≥27 dB≥26 dB≥27 dB
300-600 MHz≥23 dB≥25 dB≥23 dB
600-900 MHz≥22 dB≥24 dB≥22 dB

4.

Frequency(MHz)Attenuation(dB/100m)
Attenuation(dB/100ft)
RG58 A/URG58/URG58 C/URG58 A/URG58/URG58 C/U
50
9.79.110.82.962.773.29
10013.913.1164.243.994.88
20020.419.4246.225.917.32
4003028.437.79.158.6611.49
50034.232.241.310.439.8212.59
60037.935.749.711.5510.8815.15
86046.944.864.214.313.6619.57
100051.8497015.7914.9421.34